OPTILEVEL HLS6010D Densitiy/Dielectricity

 

The bull's-eye - Quality that speaks for itself

 

By measuring density and dielectricity OPTILEVEL has sharpened its technological edge, allowing changes in fuel quality to be detected - a key issue for today's effective quality assurance.

 

 

Taken separately, density and dielectricity measurements can provide a detailed indication of the fuel quality within a tank; taken together, however, they provide an even clearer picture of the medium in question. In generic systems, such as the controller 104M, density and volume are compensated to a standard temperature of 15°C.

 

Density

 

The hydrostatic differential pressure is measured by a pressure sensor located in the tip of the gauge. The measurement is measured integrally rather than at randomly selected points, allowing the entire amount of fuel to be measured.

 

Dielectricity

 

Dielecricity is measured at ten separate segments, allowing you to detect changes in the product.

 

The OPTILEVEL USP

 

Single gauge and opening instead of two costly sets of equipment

 

Unlike magnetostrictive sensor technology, which utilises two separate systems to calculate fill level and density, OPTILEVEL offers integrated density measurement, which means that one gauge is all you require. As a result, there's no need to create further openings in the tank for additional probes.

 

Comprehensive tank measurement - not random sampling

 

Another benefit of OPTILEVEL is that it measures the average density of the entire tank, meaning that changes can be detected almost as soon as they occur.

 

Upgrading is easy - no need for expensive and time-intensive installations

 

The new gauge can be installed quickly and easily into existing systems. OPTILEVEL can be integrated with your existing infrastructure without requiring extra lines to be laid, thus representing a considerable cost saving for you.

 

The facts speak for themselves; OPTILEVEL is number one for the job.

 

Order number

Probe length LG [mm]

Ø Tank LL [mm]

Art.No.

2100

1600

5000.06 30 21 00

2500

2000

5000.06 30 25 00

3000

2500

5000.06 30 30 00

3400

2900

5000.06 30 34 00

3500

3000

5000.06 30 35 00

Other lengths up to LG 6 m on request (Min: LL=600 mm LG=800 mm).

Technical date

 

Measurement principle

capacitive (multi-segment)

Medium dissolution

0,1 mm / 0,1°C

Length in mm

800 - 6'000

Temperature range of medium

-25°C to +100°C (Ex-Zone until +60°C)

Environmental temperature range

-25°C to +60°C

Leak tightness

IP 68

Materials with medium contact

High-grade steel and Teflon

Flange

G 1 ½", 1 ½" NPT, ...

Difference pressure sensor

Pressure range
-0.1 - 0.9 bar (rel. vs atmospheric pressure)

 

Measuring accuracy
+/- 3 g/l (from level of 800mm)

Approvals

SEV09ATEX0109, CCOE Approval P 162760

IECEXSEV10.0002

Member Login

User:
Password:
Forgot your password?

Productsearch

Category
Product

 

Hectronic news

10.01.2012 Excellent training at Hectronic

-

In a formal ceremony, commercial trainee Elena Borowskaja from Hectronic GmbH received an extra...

10.01.2012 Solutrans 2011

-

The French Hectronic subsidiary attended the Solutrans fair in Lyon this year for the third time....

24.11.2011 Hectronic sells product sector tank truck management system

-

Hectronic GmbH, Bonndorf, increases their focus on the core business segments of parking and...

  • to top
  • Print page
  • Save as PDF
  • Recommend page
  • Terms and Conditions Hectronic GmbH
end of page, go to top